| Low group frequencies (Hz) | High group frequencies (Hz) | |||
|---|---|---|---|---|
| 1209 | 1336 | 1477 | 1633 | |
| 697 | 1 | 2 | 3 | Spare. |
| 770 | 4 | 5 | 6 | Spare. |
| 852 | 7 | 8 | 9 | Spare. |
| 941 | * | 0 | # | Spare. |
| Input level (dBm0) 1004 or 1020 Hz | Minimum signal to distortion with C-message weighting |
|---|---|
| 0 to −30 | 33 dB |
| −30 to −40 | 27 dB |
| −40 to −45 | 22 dB |
| Input signal level 1 | Maximum gain deviation |
|---|---|
| 3 to −37 dBm0 | ±0.5 dB |
| −37 to −50 dBm0 | ±1 dB |
| 1 1004 Hz reference at 0 dBm0. | |
| Frequency (Hz) | Loss at 0 dBm0 input 1 |
|---|---|
| 60 | 20 dB Min. 2 |
| 300 | −1 to 3 dB |
| 600 to 2400 | 1 dB |
| 3400 | −1 to 3 dB |
| 1 (−) means less loss and ( ) means more loss. | |
| 2 Transmit End. | |
| Frequency (Hz) | Microseconds |
|---|---|
| 1000 to 2600 | 190 |
| 800 to 2800 | 350 |
| 600 to 3000 | 500 |
| 400 to 3200 | 700 |
| Test | Application criteria | Peak voltage or current | Surge waveshape | Number of applications and maximum time between | Comments |
|---|---|---|---|---|---|
| Current surge | Low impedance paths exposed to surges | 500A or lesser current (see fig. 4) | 10×1000 µs | 5 each polarity at 1 minute intervals | None. |
| 60 Hz current carrying | High or low impedance paths exposed to surges | 10A rms or lesser current (see fig. 6) | 11 Cycles of 60 Hz (0.183 Sec.) | 3 each at 1 minute intervals | None. |
| AC Power service surge voltage | AC power service connection | 2500V or 3 σ clamping V of arrester employed at 10kV/µs | 1.2×50 µs | 5 each polarity at 1 minute intervals | AC arrester, if used, must be removed. Communications line arresters, if used, remain in place. |
| Voltage surge | High impedance paths exposed to surges | 1000V or 3 σ dc breakdown of arrester employed | 10×1000 µs | 5 each polarity at 1 minute intervals | All primary arresters, if used, must be removed. |
| Arrester response delay | Paths protected by arresters, such as gas tubes, with breakdown dependent on V. rate of rise | 3 σ breakdown of arrester employed at 100V/µs of rise | 100V/µs rise decay to 1/2 V. in tube's delay time | 5 each polarity at 1 minute intervals | All primary arrestors, if used, must be removed. |