Low group frequencies (Hz) | High group frequencies (Hz) | |||
---|---|---|---|---|
1209 | 1336 | 1477 | 1633 | |
697 | 1 | 2 | 3 | Spare. |
770 | 4 | 5 | 6 | Spare. |
852 | 7 | 8 | 9 | Spare. |
941 | * | 0 | # | Spare. |
Input level (dBm0) 1004 or 1020 Hz | Minimum signal to distortion with C-message weighting |
---|---|
0 to −30 | 33 dB |
−30 to −40 | 27 dB |
−40 to −45 | 22 dB |
Input signal level 1 | Maximum gain deviation |
---|---|
3 to −37 dBm0 | ±0.5 dB |
−37 to −50 dBm0 | ±1 dB |
1 1004 Hz reference at 0 dBm0. |
Frequency (Hz) | Loss at 0 dBm0 input 1 |
---|---|
60 | 20 dB Min. 2 |
300 | −1 to 3 dB |
600 to 2400 | 1 dB |
3400 | −1 to 3 dB |
1 (−) means less loss and ( ) means more loss. | |
2 Transmit End. |
Frequency (Hz) | Microseconds |
---|---|
1000 to 2600 | 190 |
800 to 2800 | 350 |
600 to 3000 | 500 |
400 to 3200 | 700 |
Test | Application criteria | Peak voltage or current | Surge waveshape | Number of applications and maximum time between | Comments |
---|---|---|---|---|---|
Current surge | Low impedance paths exposed to surges | 500A or lesser current (see fig. 4) | 10×1000 µs | 5 each polarity at 1 minute intervals | None. |
60 Hz current carrying | High or low impedance paths exposed to surges | 10A rms or lesser current (see fig. 6) | 11 Cycles of 60 Hz (0.183 Sec.) | 3 each at 1 minute intervals | None. |
AC Power service surge voltage | AC power service connection | 2500V or 3 σ clamping V of arrester employed at 10kV/µs | 1.2×50 µs | 5 each polarity at 1 minute intervals | AC arrester, if used, must be removed. Communications line arresters, if used, remain in place. |
Voltage surge | High impedance paths exposed to surges | 1000V or 3 σ dc breakdown of arrester employed | 10×1000 µs | 5 each polarity at 1 minute intervals | All primary arresters, if used, must be removed. |
Arrester response delay | Paths protected by arresters, such as gas tubes, with breakdown dependent on V. rate of rise | 3 σ breakdown of arrester employed at 100V/µs of rise | 100V/µs rise decay to 1/2 V. in tube's delay time | 5 each polarity at 1 minute intervals | All primary arrestors, if used, must be removed. |