CFR

572.113—Neck assembly.

The head/neck assembly consists of the parts 78051-61X, rev. C; -84; -90, rev. A; -94; -98; -104, revision F; -303, rev. E;—305; -306; -307, rev. X and has a six axis neck transducer (drawing C-1709, revision D) installed in conformance with § 572.36(d).
(3) Using neck brackets 78051-303 and -307, mount the head/neck assembly to the part 572 pendulum test fixture (see § 572.33, Figure 22,) so that the midsagittal plane of the head is vertical and perpendicular to the plane of motion of the pendulum's longitudinal centerline (see § 572.33, Figure 20, except that the direction of the head/neck assembly is rotated around the superior-inferior axis by an angle of 90 degrees). Install suitable transducers or other devices necessary for measuring the “D” plane (horizontal surface at the base of the skull) rotation with respect to the pendulum's longitudinal centerline. The rotation can be measured by placing a transducer at the occipital condyles and another at the intersection of the centerline of the neck and the line extending from the base of the neck as shown in figure 52.
Time (ms) Pendulum Delta-V (m/s)
10 1.96 to 2.55.
20 4.12 to 5.10.
30 5.73 to 7.01.
40 to 70 6.27 to 7.64.
M = Mx 0.01778 Fy
Where Mx and Fy are the moment and force measured by the transducer and expressed in terms of Nm and N, respectively.
[63 FR 41470, Aug. 4, 1998, as amended at 66 FR 51882, Oct. 11, 2001]