230.70—Safe condition.
(a) Pre-departure inspection.
At the beginning of each day the locomotive is used, the steam locomotive operator shall ensure that:
(1)
The brakes on the steam locomotive and tender are in safe and suitable condition for service;
(2)
The air compressor or compressors are in condition to provide an ample supply of air for the locomotive service intended;
(3)
The devices for regulating all pressures are properly performing their functions;
(4)
The brake valves work properly in all positions; and
(5)
The water has been drained from the air-brake system.
(b) Brake pipe valve required.
Each steam locomotive shall have a brake pipe valve attached to the front of the tender, the rear of the back cab wall, or adjacent to the exit of a vestibuled cab. The words “Emergency Brake Valve” shall be clearly displayed near the valve.