| The deviation from uniform 1 profile on either rail at the midordinate of a 31-foot chord may not be more than | 
                1 | 
                1 | 
                
                    3/4
                 | 
                
                    1/2
                 | 
            
            
                | The deviation from uniform profile on either rail at the midordinate of a 62-foot chord may not be more than | 
                1 | 
                1 | 
                1 | 
                
                    3/4
                 | 
            
            
                | The deviation from uniform profile on either rail at the midordinate of a 124-foot chord may not be more than | 
                13/4
                 | 
                11/2
                 | 
                11/4
                 | 
                11/4
                 | 
            
            
                | The difference in crosslevel between any two points less than 62 feet apart may not be more than 2
                 | 
                11/2
                 | 
                11/2
                 | 
                11/2
                 | 
                11/2
                 | 
            
            
                | 
                    1 Uniformity for profile is established by placing the midpoint of the specified chord at the point of maximum measurement. | 
            
            
                | 
                    2 However, to control harmonics on jointed track with staggered joints, the crosslevel differences shall not exceed 11/4 inches in all of six consecutive pairs of joints, as created by 7 joints. Track with joints staggered less than 10 feet shall not be considered as having staggered joints. Joints within the 7 low joints outside of the regular joint spacing shall not be considered as joints for purposes of this footnote. |