Find Laws Find Lawyers Free Legal Forms USA State Laws

CFR

195.563—Which pipelines must have cathodic protection?

(a) Each buried or submerged pipeline that is constructed, relocated, replaced, or otherwise changed after the applicable date in § 195.401(c) must have cathodic protection. The cathodic protection must be in operation not later than 1 year after the pipeline is constructed, relocated, replaced, or otherwise changed, as applicable.
(b) Each buried or submerged pipeline converted under § 195.5 must have cathodic protection if the pipeline—
(1) Has cathodic protection that substantially meets § 195.571 before the pipeline is placed in service; or

Code of Federal Regulations


Footnote(s): 1 A pipeline does not have an effective external coating material if the current required to cathodically protect the pipeline is substantially the same as if the pipeline were bare.
Tips