192.463—External corrosion control: Cathodic protection.
               		
               	 	
               	 	
               	 	               	 	               	 	               	 	               	 	
               	 	
    
        
        (a) 
         Each cathodic protection system required by this subpart must provide a level of cathodic protection that complies with one or more of the applicable criteria contained in appendix D of this part. If none of these criteria is applicable, the cathodic protection system must provide a level of cathodic protection at least equal to that provided by compliance with one or more of these criteria.
     
    
        
        (b) 
         If amphoteric metals are included in a buried or submerged pipeline containing a metal of different anodic potential—
     
    
        
        (1) 
         The amphoteric metals must be electrically isolated from the remainder of the pipeline and cathodically protected; or
     
    
        
        (2) 
         The entire buried or submerged pipeline must be cathodically protected at a cathodic potential that meets the requirements of appendix D of this part for amphoteric metals.
     
    
        
        (c) 
         The amount of cathodic protection must be controlled so as not to damage the protective coating or the pipe.