Specification under which cylinder was made | Minimum test pressure(psig) 2 | Requalification period(years) |
---|---|---|
DOT 3 | 3000 psig | 5 |
DOT 3A, 3AA | 5/3 times service pressure, except noncorrosive service (see § 180.209(g) ) | 5, 10, or 12 (see § 180.209(b), (f), (h), and (j) |
DOT 3AL | 5/3 times service pressure | 5 or 12 (see § 180.209(j) and § 180.209(m) 3 ). |
DOT 3AX, 3AAX | 5/3 times service pressure | 5 |
3B, 3BN | 2 times service pressure (see § 180.209(g) ) | 5 or 10 (see § 180.209(f) ) |
3E | Test not required | |
3HT | 5/3 times service pressure | 3 (see §§ 180.209(k) and 180.213(c) ) |
3T | 5/3 times service pressure | 5 |
4AA480 | 2 times service pressure (see § 180.209(g) ) | 5 or 10 (see § 180.209(h) ) |
4B, 4BA, 4BW, 4B-240ET | 2 times service pressure, except non-corrosive service (see § 180.209(g) ) | 5, 10, or 12 (see § 180.209(e), (f), and (j) ) |
Code of Federal Regulations
1133
|
||
4D, 4DA, 4DS | 2 times service | 5 |
DOT 4E | 2 times service pressure, except non-corrosive (see § 180.209(g) ) | 5 |
4L | Test not required | |
8, 8AL | 10 or 20 (see § 180.209(i) ) | |
Exemption or special permit cylinder | See current exemption or special permit | See current exemption or special permit |
Foreign cylinder (see § 173.301(j) of this subchapter for restrictions on use) | As marked on cylinder, but not less than 5/3 of any service or working pressure marking | 5 (see §§ 180.209(l) and 180.213(d)(2) ) |
1 Any cylinder not exceeding 2 inches outside diameter and less than 2 feet in length is excepted from volumetric expansion test. | ||
2 For cylinders not marked with a service pressure, see § 173.301a(b) of this subchapter. |
Cylinders conforming to— | Used exclusively for— |
---|---|
DOT 3A, DOT 3AA, DOT 3A480X, DOT 4AA480 | Anhydrous ammonia of at least 99.95% purity. |
DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW | Butadiene, inhibited, that is commercially free from corroding components. |
DOT 3A, DOT 3A480X, DOT 3AA, DOT 3B, DOT 4AA480, DOT 4B, DOT 4BA, DOT 4BW | Cyclopropane that is commercially free from corroding components. |
DOT 3A, DOT 3AA, DOT 3A480X, DOT 4B, DOT 4BA, DOT 4BW, DOT 4E | Chlorinated hydrocarbons and mixtures thereof that are commercially free from corroding components. |
DOT 3A, DOT 3AA, DOT 3A480X, DOT 4B, DOT 4BA, DOT 4BW, DOT 4E | Fluorinated hydrocarbons and mixtures thereof that are commercially free from corroding components. |
DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4E | Liquefied hydrocarbon gas that is commercially free from corroding components. |
DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4E | Liquefied petroleum gas that meets the detail requirements limits in Table 1 of ASTM 1835, Standard Specification for Liquefied Petroleum (LP) Gases (incorporated by reference; see § 171.7 of this subchapter) or an equivalent standard containing the same limits. |
DOT 3A, DOT 3AA, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4E | Methylacetylene-propadiene, stabilized, that is commercially free from corroding components. |
DOT 3A, DOT 3AA, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW | Anhydrous mono, di,trimethylamines that are commercially free from corroding components. |
DOT 4B240, DOT 4BW240 | Ethyleneimine, stabilized. |
Date of cylinder manufacture | Shell (visual inspection) requalification | Porous filler requalification | ||
---|---|---|---|---|
Initial | Subsequent | Intial | Subsequent | |
Before January 1, 1991 | Before January 1, 2001 | 10 years | Before January 1, 2011 | Not required. |
On or after January 1, 1991 | 10 years 1 | 10 years | 5 to 20 years 2 | Not required. |
1 Years from the date of cylinder manufacture. | ||||
2 No sooner than 5 years, and no later than 20 years from the date of manufacture. |
Requalification requirement | Examination procedure 1 | Sustained Load Cracking Condemnation Criteria 2 | Requalification period (years) |
---|---|---|---|
Eddy current examination combined with visual inspection | Eddy current—In accordance with Appendix C of this partVisual inspection—In accordance with CGA Pamphlet C-6.1 (IBR; see § 171.7 of this subchapter) | Any crack in the neck or shoulder of 2 thread lengths or more | 5 |
1 The requalifier performing eddy current must be familiar with the eddy current equipment and must standardize (calibrate) the system in accordance with the requirements provided in Appendix C to this part. | |||
2 The eddy current must be applied from the inside of the cylinder's neck to detect any sustained load cracking that has expanded into the neck threads. |
Specification under which cylinder was made | Minimum test pressure (psig) 2 | Requalification period (years) |
---|---|---|
******* | ||
4B, 4BA, 4BW, 4B240ET | 2 times service pressure, except non-corrosive (see § 180.209(g) ) | 5, 7, 10, or 12 (see § 180.209(e), (f), and (j) ). |
******* | ||
DOT 4E | 2 times service pressure, except non-corrosive (see § 180.209(g) ) | 5 or 7 (see § 180.209(e) ). |