               	               		62.35-10—Flooding safety.
               		
               	 	
               	 	
               	 	               	 	               	 	               	 	               	 	
               	 	
    
        
        (a) 
         Automatic bilge pumps must—
     
    
        
        (1) 
         Be provided with bilge high level alarms that annunciate in the machinery spaces and at a manned control location and are independent of the pump controls;
     
    
        
        (2) 
         Be monitored to detect excessive operation in a specified time period; and
     
    
        
        (3) 
         Meet all applicable pollution control requirements.
     
    
        
        (b) 
         Remote controls for flooding safety equipment must remain functional under flooding conditions to the extent required for the associated equipment by  § 56.50-50 and  § 56.50-95 of this chapter.
     
    
        
        (c) 
         Remote bilge level sensors, where provided, must be located to detect flooding at an early stage and to provide redundant coverage.