(a)
Each tank shall be fitted with one or more safety relief valves designed, constructed, and flow tested in accordance with subpart or in subchapter Q (Specifications) of this chapter. Valves conforming to specification subpart shall be limited to use on tanks whose maximum allowable working pressure is not in excess of 10 pounds per square inch. With specific approval of the Commandant, such valves may be connected to the vessel in lieu of being directly fitted to the tanks.
(b)
The discharge pressure and the maximum overpressure permitted shall be in accordance with § 54.15-5.
(c)
The rate of discharge for heat input of fire must meet the following formula:
Code of Federal Regulations
Q=FGA0.82
Code of Federal Regulations
Code of Federal Regulations
157
[Please see PDF for image:
EC01FE91.022
]
Table 54.15-25(c)—Constant C
1.00 |
.606 |
(315) |
1.02 |
.611 |
(318) |
1.04 |
.615 |
(320) |
1.06 |
.620 |
(322) |
1.08 |
.624 |
(324) |
1.10 |
.628 |
(327) |
1.12 |
.633 |
(329) |
1.14 |
.637 |
(331) |
1.16 |
.641 |
(333) |
1.18 |
.645 |
(335) |
1.20 |
.649 |
(337) |
1.22 |
.652 |
(339) |
1.24 |
.658 |
(341) |
1.26 |
.660 |
(343) |
1.28 |
.664 |
(345) |
1.30 |
.667 |
(347) |
1.32 |
.671 |
(349) |
1.34 |
.674 |
(351) |
1.36 |
.677 |
(352) |
1.38 |
.681 |
(354) |
1.40 |
.685 |
(356) |
1.42 |
.688 |
(358) |
1.44 |
.691 |
(359) |
1.46 |
.695 |
(361) |
1.48 |
.698 |
(363) |
1.50 |
.701 |
(364) |
1.52 |
.704 |
(366) |
1.54 |
.707 |
(368) |
1.56 |
.710 |
(369) |
1.58 |
.713 |
(371) |
1.60 |
.716 |
(372) |
1.62 |
.719 |
(374) |
1.64 |
.722 |
(376) |
1.66 |
.725 |
(377) |
1.68 |
.728 |
(379) |
1.70 |
.731 |
(380) |
1.72 |
.734 |
(382) |
1.74 |
.736 |
(383) |
1.76 |
.739 |
(384) |
1.78 |
.742 |
(386) |
1.80 |
.745 |
(387) |
1.82 |
.747 |
(388) |
1.84 |
.750 |
(390) |
1.86 |
.752 |
(391) |
1.88 |
.755 |
(392) |
1.90 |
.758 |
(394) |
1.92 |
.760 |
(395) |
1.94 |
.763 |
(397) |
1.96 |
.765 |
(398) |
1.98 |
.767 |
(399) |
2.00 |
.770 |
(400) |
2.02 |
.772 |
(401) |
2.20 |
.792 |
(412) |
(c-1) For an independent tank that has a portion of the tank protruding above the open deck, the fire exposure factor must be calculated for the surface area above the deck and the surface area below the deck, and this calculation must be specially approved by the Commandant CG-521.
(d)
In determining the total safety valve relieving capacity, the arrangement and location of the valves on the tank will be evaluated. The valves shall be placed so that a number of valves sufficient to provide the required relieving capacity shall always be in communication with the cargo vapor phase. The possible motions which the tank may see in its intended service and attendant changes in cargo liquid level will be considered. Shut off valves shall not be installed between the vessel and the safety relief valves. Manifolds for mounting multiple relief valves may be fitted with acceptable interlocking shut off valves so arranged that the required capacity of discharge will be “lined up” at all times.
(e)
(1)
Each safety relief valve shall be tested in the presence of a marine inspector before being placed in service except as noted otherwise in paragraph (e)(2) of this section. The test shall satisfactorily show that the valve will start to discharge at the required minimum pressure.
(2)
Each safety relief valve fitted with a breaking pin and rupture disk need not be tested in the presence of a marine inspector before being placed in service. In lieu thereof, a certificate shall be furnished with the valve attested to by the manufacturer that the test requirements of paragraph (e)(1) of this section have been met.
[CGFR 68-82, 33 FR 18828, Dec. 18, 1968, as amended by CGD 74-289, 44 FR 26007, May 3, 1979; CGD 82-063b, 48 FR 4781, Feb. 3, 1983; CGD 95-072, 60 FR 50462, Sept. 29, 1995; CGD 96-041, 61 FR 50728, Sept. 27, 1996; USCG-2004-18884, 69 FR 58346, Sept. 30, 2004; USCG-2007-29018, 72 FR 53965, Sept. 21, 2007; USCG-2009-0702, 74 FR 49228, Sept. 25, 2009]