Table 28.160—Portable Fire Extinguishers for Vessels 65 Feet (19.8 Meters) or More in Length
| Safety areas, communicating corridors |
A-II |
1 in each main corridor not more than 150 feet (49.2 meters) apart. (May be located in stairways.) |
| Pilothouse |
C-I |
2 in vicinity of exit. |
| Service spaces, galleys |
B-II or C-II |
1 for each 2,500 square feet (269.1 sq. meters) or fraction thereof suitable for hazards involved. |
| Paint lockers |
B-II |
1 outside space in vicinity of exit. |
| Accessible baggage and storerooms |
A-II |
1 for each 2,500 square feet (269.1 sq. meters) or fraction thereof located in the vicinity of exits, either inside or outside the spaces. |
| Work shops and similar spaces |
A-II |
1 outside the space in vicinity of exit. |
| Machinery spaces; Internal combustion propelling machinery |
B-II |
1 for each 1,000 brake horsepower or fraction thereof but not less than 2 nor more than 6. |
| Electric propulsion motors or generator unit of open type |
C-II |
1 for each propulsion motor generator unit. |
| Auxiliary spaces |
B-II |
1 outside the space in the vicinity of exit. |
| Internal combustion machinery |
B-II |
1 outside the space in the vicinity of exit. |
| Electric emergency motors or generators |
C-II |
1 outside the space in the vicinity of exit. |