197.322—Surface-supplied helmets and masks.
               		
               	 	
               	 	
               	 	               	 	               	 	               	 	               	 	
               	 	
    
        
        (a) 
         Each surface-supplied helmet or mask must have—
     
    
        
        (1) 
         A nonreturn valve at the attachment point between helmet or mask and umbilical that closes readily and positively;
     
    
        
        (2) 
         An exhaust valve; and
     
    
        
        (3) 
         A two-way voice communication system between the diver and the dive location or bell.
     
    
        
        (b) 
         Each surface-supplied air helmet or mask must—
     
    
        
        (1) 
         Ventilate at least 4.5 ACFM at any depth at which it is operated; or
     
    
        
        (2) 
         Be able to maintain the diver's inspired carbon dioxide partial pressure below 0.02 ATA when the diver is producing carbon dioxide at the rate of 1.6 standard liters per minute.