(a)
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by Table 181.500(a) and other provisions of this section.
Table 181.500(a)
| Operating Station |
1 |
B-I, C-I |
Halon |
1.1 kg (2.5 lb). |
|
|
|
CO2 |
1.8kg (4 lb). |
|
|
|
Dry Chemical |
0.9 kg (2 lb). |
| Machinery Space |
1 |
B-II, C-II located just outside exit |
CO2 |
6.8 kg (15 lb). |
|
|
|
Dry chemical |
4.5 kg (10 lb). |
| Open Vehicle Deck |
1 for every 10 vehicles |
B-II |
Foam |
9.5 L (2.5 gal). |
|
|
|
Halon |
4.5 kg (10 lb). |
|
|
|
CO2 |
6.8 kg (15 lb). |
|
|
|
Dry Chemical |
4.5 kg (10 lb). |
| Accomodation Space |
1 for each 232.3 square meters (2,500 square feet) or fraction thereof |
A-II |
Foam Dry Chemical
|
9.5 L (2.5 gal). 4.5 kg (10 lb).
|
| Galley, Pantry, Concession Stand |
1 |
A-II, B-II |
Foam |
9.5 L (2.5 gal). |
|
|
|
Dry Chemical |
4.5 kg (10 lb). |
(b)
A vehicle deck without a fixed sprinkler system and exposed to weather must have one B-II portable fire extinguisher for every five vehicles, located near an entrance to the space.
(c)
The cognizant OCMI may permit the use of a larger portable fire extinguisher, or a semiportable fire extinguisher, in lieu of those required by this section.
(d)
The frame or support of each B-V fire extinguisher permitted by paragraph (c) of this section must be welded or otherwise permanently attached to a bulkhead or deck.
[CGD 85-080, 61 FR 982, Jan. 10, 1996; 61 FR 24464, May 15, 1996, as amended at 62 FR 51358, Sept. 30, 1997]