169.672—Wiring for power and lighting circuits.
(a)
Wiring for power and lighting circuits must have copper conductors, of 14 AWG or larger, and—
(1)
Meet Article 310-8 and Table 310-13 of the National Electrical Code;
(2)
Be listed as “50 volt boat cable”; or
(3)
Meet subpart of this chapter.
(b)
Wiring for power and lighting circuits on new vessels must have stranded conductors.
(c)
Conductors must be sized so that—
(1)
They are adequate for the loads carried; and
(2)
The voltage drop at the load terminals is not more than 10 percent.