Cargo liquid or vapor piping must:
    
    
        
        (a) 
         Be separated from other piping systems, except where an interconnection to inert gas or purge piping is required by  § 154.901(a) ;
     
    
        
        (b) 
         Not enter or pass through any accommodation, service, or control space;
     
    
        
        (c) 
         Except as allowed under  § 154.703, not enter or pass through a machinery space other than a cargo pump or compressor room;
     
    
        
        (d) 
         Be in the cargo area except:
     
    
    
        
        (2) 
         Bow and stern loading piping; and
     
    
        
        (3) 
         Emergency jettisoning piping.
     
    
        
        (e) 
         Be above the weather deck except:
     
    
    
        
        (2) 
         Pipes in a trunk traversing void spaces above a cargo containment system; and
     
    
        
        (3) 
         Pipes for draining, venting, or purging interbarrier and hold spaces;
     
    
        
        (f) 
         Connect into the cargo containment system above the weather deck except:
     
    
        
        (1) 
         Pipes in a trunk traversing void spaces above a cargo containment system; and
     
    
        
        (2) 
         Pipes for draining, venting, or purging interbarrier and hold spaces.
     
    
        
        (g) 
         Be inboard of the transverse cargo tank location required by  § 154.235, except for athwartship shore connection manifolds not subject to internal pressure at sea.