Table 132.220—Carriage of Portable and Semiportable Fire Extinguishers
|
| Safety areas: Communicating passageways |
A-II |
1. In each main passageway, not more than 45.7 meters (150 feet) apart (permissible in stairways). |
| Pilothouse |
C-I |
2. In vicinity of exit. |
| Service spaces: Galleys |
B-II or C-11 |
1. For each 230 square meters (2,500 feet2) or fraction thereof, suitable for hazards involved. |
| Paint lockers |
B-II |
1. Outside space, in vicinity of exit. |
| Accessible baggage and storerooms |
A-II |
1. For each 230 square meters (2,500 feet2) or fraction thereof, located in vicinity of exits, either inside or outside spaces. |
| Work shops and similar spaces |
A-II |
1. Outside space in vicinity of exit. |
| Machinery spaces: Internal-combustion propulsion-machinery |
B-II |
1. For each 1,000 brake horsepower, but not fewer than 2 nor more than 6. |
|
B-III |
1. Required. (1), (2) |
| Electric propulsion motors or generators of open type |
C-II |
1. For each propulsion motor or generator unit. |
| Auxiliary spaces: Internal combustion |
B-II |
1. Outside space in vicinity of exit. (2) |
| Electric motors and emergency generators |
C-II |
1. Outside space in vicinity of exit. (2) |
| (1) Not required where a fixed gaseous fire-extinguishing system is installed. |
| (2) Not required on vessels of less than 300 gross tons. |