Space protected | Minimum number required | Type extinguisher permitted | ||
---|---|---|---|---|
CG class | Medium | Min. size | ||
Operating station | 1 | B-I, C-I | Halon | 1.1 kg (2.5 lb) |
CO2 | 1.8 kg (4 lb) | |||
Dry chemical | 0.9 kg (2 lb) | |||
Code of Federal Regulations
329
|
||||
Machinery space | 1 | B-II, C-II located just outside exit | Halon | 4.5 kg (10 lb) |
CO2 | 6.8 kg (15 lb) | |||
Dry chemical | 4.5 kg (10 lb) | |||
Open vehicle deck | 1 for every 10 vehicles | B-II | Foam | 9.5 L (2.5 gal) |
Halon | 4.5 kg (10 lb) | |||
CO2 | 6.8 kg (15 lb) | |||
Dry chemical | 4.5 kg (10 lb) | |||
Accommodation space | 1 for each 232.3 square meters (2,500 square feet) or fraction thereof | A-II | Foam | 9.5 L (2.5 gal) |
Dry chemical | 4.5 kg (10 lb) | |||
Galley, pantry, concession stand | 1 | A-II | Foam | 9.5 L (2.5 gal) |
B-II | Dry chemical | 4.5 kg (10 lb) |