(a)
For all landfills subject to the reporting requirements of this subpart, calculate annual modeled CH4 generation according to the applicable requirements in paragraphs (a)(1) through (a)(3) of this section.
(1)
Calculate annual modeled CH4 generation using Equation HH-1 of this section.
(2)
For years when material-specific waste quantity data are available, apply Equation HH-1 of this section for each waste quantity type and sum the CH4 generation rates for all waste types to calculate the total modeled CH4 generation rate for the landfill. Use the appropriate parameter values for k, DOC, MCF, DOCF, and F shown in Table HH-1 of this subpart. The annual quantity of each type of waste disposed must be calculated as the sum of the daily quantities of waste (of that type) disposed. You may use the bulk waste parameters for a portion of your waste materials when using the material-specific modeling approach for mixed waste streams that cannot be designated to a specific material type. For years when waste composition data are not available, use the bulk waste parameter values for k and DOC in Table HH-1 to this subpart for the total quantity of waste disposed in those years.
(3)
Beginning in the first emissions reporting year and for each year thereafter, if scales are in place, you must determine the annual quantity of waste (in metric tons as received, i.e., wet weight) disposed of in the landfill using paragraph (a)(3)(i) of this section for all containers and for all vehicles used to haul waste to the landfill, except for passenger cars, light duty pickup trucks, or waste loads that cannot be measured using the scales due to physical limitations (load cannot physically access or fit on the scale) and/or operational limitations of the scale (load exceeding the limits or sensitivity range of the scale). If scales are not in place, you must use paragraph (a)(3)(ii) of this section to determine the annual quantity of waste disposed. For waste hauled to the landfill in passenger cars or light duty pickup trucks, you may use either paragraph (a)(3)(i) or paragraph (a)(3)(ii) of this section to determine the annual quantity of waste disposed. For loads that cannot be measured using the scales due to physical and/or operational limitations of the scale, you must use paragraph (a)(3)(ii) of this section or similar engineering calculations to determine the annual quantity of waste disposed. The approach used to determine the annual quantity of waste disposed of must be documented in the monitoring plan.
(i)
Use direct mass measurements of each individual load received at the landfill using either of the following methods:
(A)
Weigh using mass scales each vehicle or container used to haul waste as it enters the landfill or disposal area; weigh using mass scales each vehicle or container after it has off-loaded the waste; determine the quantity of waste received from the individual load as the difference in the two mass measurements; and determine the annual quantity of waste received as the sum of all waste loads received during the year. Alternatively, you may determine annual quantity of waste by summing the weights of all vehicles and containers entering the landfill and subtracting from it the sum of all the weights of vehicles and containers after they have off-loaded the waste in the landfill.
(B)
Weigh using mass scales each vehicle or container used to haul waste as it enters the landfill or disposal area; determine a representative tare weight by vehicle or container type by weighing no less than 5 of each type of vehicle or container after it has off-loaded the waste; determine the quantity of waste received from the individual load as the difference between the measured weight in and the tare weight determined for that container/vehicle type; and determine the annual quantity of waste received as the sum of all waste loads received during the year.
(ii)
Determine the working capacity in units of mass for each type of container or vehicle used to haul waste to the landfill (e.g., using volumetric capacity and waste density measurements; direct measurement of a selected number of passenger vehicles and light duty pick-up trucks; or similar methods); record the number of loads received at the landfill by vehicle/container type; calculate the annual mass per vehicle/container type as the mass product of the number of loads of that vehicle/container multiplied by its working capacity; and calculate the annual quantity of waste received as the sum of the annual mass per vehicle/container type across all of the vehicle/container types used to haul waste to the landfill.
(4)
For years prior to the first emissions reporting year, use methods in paragraph (a)(3) of this section when waste disposal quantity data are readily available. When waste disposal quantity data are not readily available, WX shall be estimated using one of the applicable methods in paragraphs (a)(4)(i) through (a)(4)(iii) of this section. You must determine which method is most applicable to the conditions and disposal history of your facility. Historical waste disposal quantities should only be determined once, as part of the first annual report, and the same values should be used for all subsequent annual reports, supplemented by the next year's data on new waste disposal.
(i)
Assume all prior years waste disposal quantities are the same as the waste quantity in the first year for which waste quantities are available.
(ii)
Use the estimated population served by the landfill in each year, the values for national average per capita waste disposal rates found in Table HH-2 to this subpart, and calculate the waste quantity landfilled using Equation HH-2 of this section.
(iii)
Use a constant average waste disposal quantity calculated using Equation HH-3 of this section for each year the landfill was in operation (i.e., from the first year accepting waste until the last year for which waste disposal data is unavailable, inclusive).
(b)
For landfills with gas collection systems, calculate the quantity of CH4 destroyed according to the requirements in paragraphs (b)(1) and (b)(2) of this section.
(1)
If you continuously monitor the flow rate, CH4 concentration, temperature, pressure, and, if necessary, moisture content of the landfill gas that is collected and routed to a destruction device (before any treatment equipment) using a monitoring meter specifically for CH4 gas, as specified in § 98.344, you must use this monitoring system and calculate the quantity of CH4 recovered for destruction using Equation HH-4 of this section. A fully integrated system that directly reports CH4 content requires no other calculation than summing the results of all monitoring periods for a given year.
(2)
If you do not continuously monitor according to paragraph (b)(1) of this section, you must determine the flow rate, CH4 concentration, temperature, pressure, and moisture content of the landfill gas that is collected and routed to a destruction device (before any treatment equipment) according to the requirements in paragraphs (b)(2)(i) through (b)(2)(iii) of this section and calculate the quantity of CH4 recovered for destruction using Equation HH-4 of this section.
(i)
Continuously monitor gas flow rate and determine the cumulative volume of landfill gas each week and the cumulative volume of landfill gas each year that is collected and routed to a destruction device (before any treatment equipment). Under this option, the gas flow meter is not required to automatically correct for temperature, pressure, or, if necessary, moisture content. If the gas flow meter is not equipped with automatic correction for temperature, pressure, or, if necessary, moisture content, you must determine these parameters as specified in paragraph (b)(2)(iii) of this section.
(ii)
Determine the CH4 concentration in the landfill gas that is collected and routed to a destruction device (before any treatment equipment) in a location near or representative of the location of the gas flow meter at least once each calendar week; if only one measurement is made each calendar week, there must be at least three days between measurements.
(iii)
If the gas flow meter is not equipped with automatic correction for temperature, pressure, or, if necessary, moisture content:
(A)
Determine the temperature and pressure in the landfill gas that is collected and routed to a destruction device (before any treatment equipment) in a location near or representative of the location of the gas flow meter at least once each calendar week; if only one measurement is made each calendar week, there must be at least three days between measurements.
(B)
If the CH4 concentration is determined on a dry basis and flow is determined on a wet basis or CH4 concentration is determined on a wet basis and flow is determined on a dry basis, and the flow meter does not automatically correct for moisture content, determine the moisture content in the landfill gas that is collected and routed to a destruction device (before any treatment equipment) in a location near or representative of the location of the gas flow meter at least once each calendar week; if only one measurement is made each calendar week, there must be at least three days between measurements.
(c)
For all landfills, calculate CH4 generation (adjusted for oxidation in cover materials) and actual CH4 emissions (taking into account any CH4 recovery, and oxidation in cover materials) according to the applicable methods in paragraphs (c)(1) through (c)(3) of this section.
(1)
Calculate CH4 generation, adjusted for oxidation, from the modeled CH4 (GCH
[=E T=0362]4 from Equation HH-1 of this section) using Equation HH-5 of this section.
(2)
For landfills that do not have landfill gas collection systems, the CH4 emissions are equal to the CH4 generation (MG) calculated in Equation HH-5 of this section.
(3)
For landfills with landfill gas collection systems, calculate CH4 emissions using the methodologies specified in paragraphs (c)(3)(i) and (c)(3)(ii) of this section.
(i)
Calculate CH4 emissions from the modeled CH4 generation and measured CH4 recovery using Equation HH-6 of this section.
(ii)
Calculate CH4 generation and CH4 emissions using measured CH4 recovery and estimated gas collection efficiency and Equations HH-7 and HH-8 of this section.
Code of Federal Regulations