[g/bhp-hr] | ||
Line-haul 1 cycle standard | Switch cycle standard | |
---|---|---|
NOX | 9.5 | 14.0 |
PM | 0.60 | 0.72 |
CO | 5.0 | 8.0 |
THC | 1.00 | 2.10 |
NMHC | 1.00 | 2.10 |
THCE | 1.00 | 2.10 |
Code of Federal Regulations
423
|
||
1 Line-haul standards do not apply to Tier 0 switch locomotives. |
[g/bhp-hr] | ||
Line-haul cycle standard | Switch cycle standard | |
---|---|---|
NOX | 7.4 | 11.0 |
PM | 0.45 | 0.54 |
CO | 2.2 | 2.5 |
THC | 0.55 | 1.20 |
NMHC | 0.55 | 1.20 |
THCE | 0.55 | 1.20 |
[g/bhp-hr] | ||
Line-haul cycle standard | Switch cycle standard | |
---|---|---|
NOX | 5.5 | 8.1 |
PM | 0.20 | 0.24 |
CO | 1.5 | 2.4 |
THC | 0.30 | 0.60 |
NMHC | 0.30 | 0.60 |
THCE | 0.30 | 0.60 |
[Percent Opacity] | |||
Steady-state | 30-sec peak | 3-sec peak | |
---|---|---|---|
Tier 0 | 30 | 40 | 50 |
Tier 1 | 25 | 40 | 50 |
Tier 2 | 20 | 40 | 50 |
[g/bhp-hr] | ||||
Line-haul cycle | Switch cycle | |||
---|---|---|---|---|
CO | PM | CO | PM | |
Tier 0 | 10.0 | 0.30 | 12.0 | 0.36 |
Tier 1 | 10.0 | 0.22 | 12.0 | 0.27 |