Calibration Data Measurements
Barometric pressure (corrected) |
PB
|
kPa |
±.340 kPa. |
Ambient temperature |
TA
|
°C |
±.28 °C. |
Air temperature into metering venturi |
ETI |
°C |
±1.11 °C. |
Pressure drop between the inlet and throat of metering venturi |
EDP |
kPa |
±0.012 kPa. |
Air flow |
QS
|
m3/min. |
±0.5 percent of NIST value. |
Air temperature at CVS pump inlet |
PTI |
°C |
±1.11 °C. |
Pressure depression at CVS pump inlet |
PPI |
kPa |
±0.055 kPa. |
Pressure head at CVS pump outlet |
PPO |
kPa |
±0.055 kPa. |
Air temperature at CVS pump outlet (optional) |
PTO |
°C |
±1.11 °C. |
Pump revolutions during test period |
N |
Revs |
±1 Rev. |
Elapsed time for test period |
t |
s |
±0.5 s. |