90.304—Test equipment overview.
               		
               	 	
               	 	
               	 	               	 	               	 	               	 	               	 	
               	 	
    
        
        (a) 
         All engines subject to this subpart are tested for exhaust emissions. Engines are operated on dynamometers  meeting the specification given in  § 90.305.
     
    
        
        (b) 
         The exhaust is tested for gaseous emissions using a raw gas sampling system as described in  § 90.414 or a constant volume sampling (CVS) system as described in  § 90.421. Both systems require analyzers (see paragraph (c) of this section) specific to the pollutant being measured.
     
    
        
        (c) 
         Analyzers used are a non-dispersive infrared (NDIR) absorption type for carbon monoxide and carbon dioxide analysis; paramagnetic (PMD), zirconia (ZRDO), or electrochemical type (ECS) for oxygen analysis; a flame ionization (FID) or heated flame ionization (HFID) type for hydrocarbon analysis; and a chemiluminescent detector (CLD) or heated chemiluminescent detector (HCLD) for oxides of nitrogen analysis.