Parameter | Symbol | Units | Sensor-readout tolerances |
---|---|---|---|
Barometric pressure (corrected) | P B | kPa | ±.34 kPa |
Ambient temperature | T A | °C | ±.3 °C |
Air temperature into metering venturi | ETI | °C | ±1.1 °C |
Pressure drop between the inlet and throat of metering venturi | EDP | kPa | ±.01 kPa |
Code of Federal Regulations
116
|
|||
Air flow | Q S | m3/min | ±.5% of NIST value. |
Air temperature at CVS pump inlet | PTI | °C | ±1.1 °C |
Pressure depression at CVS pump inlet | PPI | kPa | ±.055 kPa |
Pressure head at CVS pump outlet | PPO | kPa | ±.055 kPa |
Air temperature at CVS pump outlet (optional) | PTO | °C | ±1.1 °C |
Pump revolutions during test period | N | Revs | ±1 Rev. |
Elapsed time for test period | t | s | ±.5 s. |
Parameter | Symbol | Units | Tolerances |
---|---|---|---|
Barometric pressure (corrected) | PB | kPa (Inches Hg) | 0.034 (0.01). |
Air temperature, flowmeter | ETI | deg.C (deg.F) | 0.14 (0.25). |
Pressure depression upstream of LFE | EPI | kPa(Inches H2O) | 0.012 (0.05). |
Pressure drop across LFE matrix | EDP | kPa (Inches H2O) | 0.001 (0.005). |
Air flow | Qs | m3/min. (Ft3/min) | 0.5 pct. |
CFV inlet depression | PPI | kPa (Inches Hg) | 0.055 (0.016). |
CFV outlet pressure | PPO | kPa (Inches Hg) | 0.17 (0.05). |
Temperature at venturi inlet | Tv | deg.C (deg.F) | 0.28 (0.5) |
Specific gravity of manometer fluid | Sp.Gr | (1.75 oil). |