| Parameter | Symbol | Units | Sensor-readout tolerances |
|---|---|---|---|
| Barometric pressure (corrected) | P B | kPa | ±.34 kPa |
| Ambient temperature | T A | °C | ±.3 °C |
| Air temperature into metering venturi | ETI | °C | ±1.1 °C |
| Pressure drop between the inlet and throat of metering venturi | EDP | kPa | ±.01 kPa |
|
Code of Federal Regulations
116
|
|||
| Air flow | Q S | m3/min | ±.5% of NIST value. |
| Air temperature at CVS pump inlet | PTI | °C | ±1.1 °C |
| Pressure depression at CVS pump inlet | PPI | kPa | ±.055 kPa |
| Pressure head at CVS pump outlet | PPO | kPa | ±.055 kPa |
| Air temperature at CVS pump outlet (optional) | PTO | °C | ±1.1 °C |
| Pump revolutions during test period | N | Revs | ±1 Rev. |
| Elapsed time for test period | t | s | ±.5 s. |
| Parameter | Symbol | Units | Tolerances |
|---|---|---|---|
| Barometric pressure (corrected) | PB | kPa (Inches Hg) | 0.034 (0.01). |
| Air temperature, flowmeter | ETI | deg.C (deg.F) | 0.14 (0.25). |
| Pressure depression upstream of LFE | EPI | kPa(Inches H2O) | 0.012 (0.05). |
| Pressure drop across LFE matrix | EDP | kPa (Inches H2O) | 0.001 (0.005). |
| Air flow | Qs | m3/min. (Ft3/min) | 0.5 pct. |
| CFV inlet depression | PPI | kPa (Inches Hg) | 0.055 (0.016). |
| CFV outlet pressure | PPO | kPa (Inches Hg) | 0.17 (0.05). |
| Temperature at venturi inlet | Tv | deg.C (deg.F) | 0.28 (0.5) |
| Specific gravity of manometer fluid | Sp.Gr | (1.75 oil). |