Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
Subpart C—BAT Effluent Limitations
|
Metric units—mg/m2 of area processed or coated |
Chromium |
16.34 |
0.53 |
6.62 |
0.22 |
Lead |
5.84 |
0.19 |
5.06 |
0.16 |
Nickel |
54.85 |
1.78 |
38.90 |
1.26 |
Zinc |
51.74 |
1.68 |
21.79 |
1.71 |
Aluminum |
176.98 |
5.74 |
72.35 |
2.35 |
Iron |
47.85 |
1.55 |
24.51 |
0.80 |
|
English units—pounds per 1 million ft2 of area processed or coated |
Chromium |
3.35 |
0.11 |
1.36 |
0.05 |
Lead |
1.20 |
0.04 |
1.04 |
0.03 |
Nickel |
11.24 |
0.37 |
7.97 |
0.26 |
Zinc |
10.60 |
0.35 |
4.46 |
0.35 |
Aluminum |
36.25 |
1.18 |
14.82 |
0.48 |
Iron |
9.80 |
0.32 |
5.02 |
0.16 |
Code of Federal Regulations
[47 FR 53184, Nov. 24, 1982, as amended at 50 FR 36544, Sept. 6, 1985]
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
Subpart C—BAT Effluent Limitations
|
Metric units—mg/m2 of area processed or coated |
Chromium |
16.34 |
0.53 |
6.62 |
0.22 |
Lead |
5.84 |
0.19 |
5.06 |
0.16 |
Nickel |
54.85 |
1.78 |
38.90 |
1.26 |
Zinc |
51.74 |
1.68 |
21.79 |
1.71 |
Aluminum |
176.98 |
5.74 |
72.35 |
2.35 |
Iron |
47.85 |
1.55 |
24.51 |
0.80 |
|
English units—pounds per 1 million ft2 of area processed or coated |
Chromium |
3.35 |
0.11 |
1.36 |
0.05 |
Lead |
1.20 |
0.04 |
1.04 |
0.03 |
Nickel |
11.24 |
0.37 |
7.97 |
0.26 |
Zinc |
10.60 |
0.35 |
4.46 |
0.35 |
Aluminum |
36.25 |
1.18 |
14.82 |
0.48 |
Iron |
9.80 |
0.32 |
5.02 |
0.16 |
Code of Federal Regulations