Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart that introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and must achieve the following pretreatment standards for existing sources (PSES):
(a)
Sintering operations with wet air pollution control system. The following table presents PSES for sintering operations with wet air pollution control systems:
Subpart B—Pretreatment Standards for Existing Sources (PSES)
Ammonia-N 2,3
|
0.0150 |
0.00501 |
Cyanide 2
|
0.00300 |
0.00150 |
Phenols (4AAP) 2
|
0.000100 |
0.0000501 |
Lead |
0.000451 |
0.000150 |
Zinc |
0.000676 |
0.000225 |
2,3,7,8-TCDF |
<ML |
|
1 Pounds per thousand lb of product. |
2 The pretreatment standards for these parameters apply only when sintering wastewater is co-treated with ironmaking wastewater. |
3 The pretreatment standards for ammonia are not applicable to sources that discharge to a POTW with nitrification capability (defined at § 420.02(s)
). |
(b) Sintering operations with dry air pollution control system.
There shall be no discharge of process wastewater pollutants to POTWs.
[67 FR 64265, Oct. 17, 2002]