417.165—Standards of performance for new sources.

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of anhydrous product)
BOD5 0.10 0.05
COD 0.44 .22
TSS 0.01 .005
Surfactants 0.10 .05
Oil and grease 0.01 .005
pH (1) (1)
English units (pounds per 1,000 lb of anhydrous product)
BOD5 0.10 0.05
COD 0.44 .22
TSS 0.01 .005
Surfactants 0.10 .05
Oil and grease 0.01 .005
pH (1) (1)
1 Within the range 6.0 to 9.0.
Effluent characteristic Effluent limitations
Metric units (kilograms per 1,000 kg of anhydrous product)
BOD5 0.02.
COD 0.07.
TSS 0.002.
Surfactants 0.02.
Oil and grease 0.002.
pH Within the range 6.0 to 9.0.
English units (pounds per 1,000 lb of anhydrous product)
BOD5 0.02.
COD 0.07.
TSS 0.002.
Surfactants 0.02.
Oil and grease 0.002.
pH Within the range 6.0 to 9.0.