(a)
THC determination and THC/CH
4
initial contamination corrections. (1) If we require you to determine THC emissions, calculate x
THC[THC-FID]cor using the initial THC contamination concentration x
THC[THC−FID]init from § 1065.520 as follows:
(2)
For the NMHC determination described in paragraph (b) of this section, correct xTHC[THC-FID] for initial HC contamination using Eq. 1065.660-1. You may correct xTHC[NMC-FID] for initial contamination of the CH4 sample train using Eq. 1065.660-1, substituting in CH4 concentrations for THC.
(3)
For the CH4 determination described in paragraph (c) of this section, you may correct xTHC[NMC-FID] for initial contamination of the CH4 sample train using Eq. 1065.660-1, substituting in CH4 concentrations for THC.
(b) NMHC determination.
Use one of the following to determine NMHC concentration, xNMHC :
(1)
If you do not measure CH4, you may determine NMHC concentrations as described in § 1065.650(c)(1)(vi).
(2)
For nonmethane cutters, calculate x
NMHC using the nonmethane cutter's penetration fractions (PF) of CH4 and C2 H6 from § 1065.365, and using the HC contamination and dry-to-wet corrected THC concentration x
THC[THC-FID]cor as determined in paragraph (a) of this section.
(i)
Use the following equation for penetration fractions determined using an NMC configuration as outlined in § 1065.365(d) :
Code of Federal Regulations
Example:
Code of Federal Regulations
x
THC[THC-FID]cor = 150.3 µmol/mol
Code of Federal Regulations
x
THC[NMC-FID]cor = 20.5 µmol/mol
Code of Federal Regulations
RFPF
C2H6[NMC-FID] = 0.019
Code of Federal Regulations
RF
CH4[THC-FID] = 1.05
Code of Federal Regulations
x
NMHC = 131.4 µmol/mol
(ii)
For penetration fractions determined using an NMC configuration as outlined in section § 1065.365(e), use the following equation:
Code of Federal Regulations
Example:
Code of Federal Regulations
x
THC[THC-FID]cor = 150.3 µmol/mol
Code of Federal Regulations
PF
CH4[NMC-FID] = 0.990
Code of Federal Regulations
x
THC[NMC-FID]cor = 20.5 µmol/mol
Code of Federal Regulations
PF
C2H6[NMC-FID] = 0.020
Code of Federal Regulations
x
NMHC = 132.3 µmol/mol
(iii)
For penetration fractions determined using an NMC configuration as outlined in section § 1065.365(f), use the following equation:
Code of Federal Regulations
Example:
Code of Federal Regulations
x
THC[THC-FID]cor = 150.3 µmol/mol
Code of Federal Regulations
PF
CH4[NMC-FID] = 0.990
Code of Federal Regulations
x
THC[NMC-FID]cor = 20.5 µmol/mol
Code of Federal Regulations
RFPF
C2H6[NMC-FID] = 0.019
Code of Federal Regulations
RF
CH4[THC-FID] = 0.980
Code of Federal Regulations
x
NMHC = 132.5 µmol/mol
(3)
For a gas chromatograph, calculate xNMHC using the THC analyzer's response factor (RF) for CH4, from § 1065.360, and the HC contamination and dry-to-wet corrected initial THC concentration xTHC[THC-FID]cor as determined in paragraph (a) of this section as follows:
Where:
Code of Federal Regulations
x
NMHC = concentration of NMHC.
Code of Federal Regulations
x
THC[THC-FID]cor = concentration of THC, HC contamination and dry-to-wet corrected, as measured by the THC FID.
Code of Federal Regulations
x
CH4 = concentration of CH4, HC contamination (optional) and dry-to-wet corrected, as measured by the gas chromatograph FID.
Code of Federal Regulations
RF
CH4[THC-FID] = response factor of THC-FID to CH4.
Code of Federal Regulations
Example:
Code of Federal Regulations
x
THC[THC-FID][cor = 145.6 µmol/mol
Code of Federal Regulations
RF
CH4[THC-FID] = 0.970
Code of Federal Regulations
x
CH4 = 18.9 µmol/mol
Code of Federal Regulations
x
NMHC = 145.6−0.970 · 18.9
Code of Federal Regulations
x
NMHC = 127.3 µmol/mol
(c)
CH
4
determination. Use one of the following methods to determine CH4 concentration, x
CH4 :
(1)
For nonmethane cutters, calculate x
CH4 using the nonmethane cutter's penetration fractions (PF) of CH4 and C2 H6 from § 1065.365, using the dry-to-wet corrected CH4 concentration x
THC[NMC-FID]cor as determined in paragraph (a) of this section and optionally using the CH4 contamination correction under paragraph (a) of this section.
(i)
Use the following equation for penetration fractions determined using an NMC configuration as outlined in § 1065.365(d) :
Where:
Code of Federal Regulations
x
CH4 = concentration of CH4.
Code of Federal Regulations
x
THC[NMC-FID]cor = concentration of THC, HC contamination (optional) and dry-to-wet corrected, as measured by the NMC FID during sampling through the NMC.
Code of Federal Regulations
x
THC[THC-FID]cor = concentration of THC, HC contamination and dry-to-wet corrected, as measured by the THC
Code of Federal Regulations
713
FID during sampling while bypassing the NMC.
Code of Federal Regulations
RFPF
C2H6[NMC-FID] = the combined ethane response factor and penetration fraction of the nonmethane cutter, according to § 1065.365(d)
.
Code of Federal Regulations
RF
CH4[THC-FID] = response factor of THC FID to CH4, according to § 1065.360(d)
.
Code of Federal Regulations
Example:
Code of Federal Regulations
x
THC[NMC-FID]cor = 10.4 µmol/mol
Code of Federal Regulations
x
THC[THC-FID]cor = 150.3 µmol/mol
Code of Federal Regulations
RFPF
C2H6[NMC-FID] = 0.019
Code of Federal Regulations
RF
CH4[THC-FID] = 1.05
Code of Federal Regulations
x
CH4 = 7.69 µmol/mol
(ii)
For penetration fractions determined using an NMC configuration as outlined in § 1065.365(e), use the following equation:
Where:
Code of Federal Regulations
x
CH4 = concentration of CH4.
Code of Federal Regulations
x
THC[NMC-FID]cor = concentration of THC, HC contamination (optional) and dry-to-wet corrected, as measured by the NMC FID during sampling through the NMC.
Code of Federal Regulations
x
THC[THC-FID]cor = concentration of THC, HC contamination and dry-to-wet corrected, as measured by the THC FID during sampling while bypassing the NMC.
Code of Federal Regulations
PF
C2H6[NMC-FID] = nonmethane cutter ethane penetration fraction, according to § 1065.365(e)
.
Code of Federal Regulations
RF
CH4[THC-FID] = response factor of THC FID to CH4, according to § 1065.360(d)
.
Code of Federal Regulations
PF
CH4[NMC-FID] = nonmethane cutter CH4 penetration fraction, according to § 1065.365(e)
.
Code of Federal Regulations
Example:
Code of Federal Regulations
x
THC[NMC-FID]cor = 10.4 µmol/mol
Code of Federal Regulations
x
THC[THC-FID]cor = 150.3 µmol/mol
Code of Federal Regulations
PF
C2H6[NMC-FID] = 0.020
Code of Federal Regulations
RF
CH4[THC-FID] = 1.05
Code of Federal Regulations
PF
CH4[NMC-FID] = 0.990
Code of Federal Regulations
x
CH4 = 7.25 µmol/mol
(iii)
For penetration fractions determined using an NMC configuration as outlined in § 1065.365(f), use the following equation:
Where:
Code of Federal Regulations
x
CH4 = concentration of CH4.
Code of Federal Regulations
x
THC[NMC-FID]cor = concentration of THC, HC contamination (optional) and dry-to-wet corrected, as measured by the NMC FID during sampling through the NMC.
Code of Federal Regulations
x
THC[THC-FID]cor = concentration of THC, HC contamination and dry-to-wet corrected, as measured by the THC FID during sampling while bypassing the NMC.
Code of Federal Regulations
RFPF
C2H6[NMC-FID] = the combined ethane response factor and penetration fraction of the nonmethane cutter, according to § 1065.365(f)
.
Code of Federal Regulations
PF
CH4[NMC-FID] = nonmethane cutter CH4 penetration fraction, according to § 1065.365(f)
.
Code of Federal Regulations
RF
CH4[THC-FID] = response factor of THC FID to CH4, according to § 1065.360(d)
.
Code of Federal Regulations
Example:
Code of Federal Regulations
x
THC[NMC-FID]cor = 10.4 µmol/mol
Code of Federal Regulations
x
THC[THC-FID]cor = 150.3 µmol/mol
Code of Federal Regulations
714
Code of Federal Regulations
RFPF
C2H6[NMC-FID] = 0.019
Code of Federal Regulations
PF
CH4[NMC-FID] = 0.990
Code of Federal Regulations
RF
CH4[THC-FID] = 1.05
Code of Federal Regulations
x
CH4 = 7.78 µmol/mol
(2)
For a gas chromatograph, xCH4 is the actual dry-to-wet corrected CH4 concentration as measured by the analyzer.
Code of Federal Regulations
[73 FR 37336, June 30, 2008, as amended at 73 FR 59339, Oct. 8, 2008; 74 FR 56516, Oct. 30, 2009; 75 FR 68464, Nov. 8, 2010]