Table 1 of § 1065.202
—Data Recording and Control Minimum Frequencies
§ 1065.510
|
Speed and torque during an engine step-map |
1 Hz |
1 mean value per step. |
§ 1065.510
|
Speed and torque during an engine sweep-map |
5 Hz |
1 Hz means. |
§ 1065.514
, § 1065.530
|
Transient duty cycle reference and feedback speeds and torques |
5 Hz |
1 Hz means. |
§ 1065.514
, § 1065.530
|
Steady-state and ramped-modal duty cycle reference and feedback speeds and torques |
1 Hz |
1 Hz. |
§ 1065.520
, § 1065.530
, § 1065.550
|
Continuous concentrations of raw or dilute analyzers |
N/A |
1 Hz. |
§ 1065.520
, § 1065.530
, § 1065.550
|
Batch concentrations of raw or dilute analyzers |
N/A |
1 mean value per test interval. |
§ 1065.530
, § 1065.545
|
Diluted exhaust flow rate from a CVS with a heat exchanger upstream of the flow measurement |
N/A |
1 Hz. |
§ 1065.530
, § 1065.545
|
Diluted exhaust flow rate from a CVS without a heat exchanger upstream of the flow measurement |
5 Hz |
1 Hz means. |
§ 1065.530
, § 1065.545
|
Intake-air or raw-exhaust flow rate |
N/A |
1 Hz means. |
§ 1065.530
, § 1065.545
|
Dilution air if actively controlled |
5 Hz |
1 Hz means. |
§ 1065.530
|
Sample flow from a CVS that has a heat exchanger |
1 Hz |
1 Hz. |
§ 1065.530
, § 1065.545
|
Sample flow from a CVS does not have a heat exchanger |
5 Hz |
1 Hz mean. |