I. Support facilities [allowable square feet (or metric equivalent) per facility for VA participation]: | |
Administrator | 200 |
Assistant administrator | 150 |
Medical officer, director of nursing or equivalent | 150 |
Nurse and dictation area | 120 |
General administration (each office/person) | 120 |
Clerical staff (each) | 80 |
Computer area | 40 |
Conference room (consultation area, in-service training) | 500 (for each room) |
Lobby/waiting area. (150 minimum/600 maximum per facility) | 3 (per bed) |
Public/resident toilets (male/female) | 25 (per fixture) |
Pharmacy 1 | |
Dietetic service 1 | |
Dining area | 20 (per bed) |
Canteen/retail sales | 2 (per bed) |
Vending machines (450 max. per facility) | 1 (per bed) |
Resident toilets (male/female) | 25 (per fixture) |
Child day care 1 | |
Medical support (staff offices/exam/treatment room/family counseling, etc.) | 140 (for each room) |
Barber and/or beauty shops | 140 |
Mail room | 120 |
Janitor's closet | 40 |
Multipurpose room | 15 (per bed) |
Employee lockers | 6 (per employee) |
Employee lounge (500 max. per facility) | 120 |
Employee toilets | 25 (per fixture) |
Chapel | 450 |
Physical therapy | 5 (per bed) |
Office, if required | 120 |
Occupational therapy | 5 (per bed). |
Office, if required | 120 |
Library | 1.5 (per bed) |
Building maintenance storage | 2.5 (per bed) |
Resident storage | 6 (per bed) |
General warehouse storage | 6 (per bed) |
Medical/dietary/pharmacy | 7 (per bed) |
General laundry 1 | |
Code of Federal Regulations
1045
|
|
II. Bed units: | |
One | 150 |
Two | 245 |
Large two-bed per unit | 305 |
Four | 460 |
Lounge areas (resident lounge with storage) | 8 (per bed) |
Resident quiet room | 3 (per bed) |
Clean utility | 120 |
Soiled utility | 105 |
Linen storage | 150 |
General storage | 100 |
Nurses station, ward secretary | 260 |
Medication room | 75 |
Exam/Treatment room | 140 |
Waiting area | 50 |
Unit supply and equipment | 50 |
Staff toilet | 25 (per fixture) |
Stretcher/wheelchair storage | 100 |
Kitchenette | 150 |
Janitor's closet | 40 |
Resident laundry | 125 |
Trash collection | 60 |
III. Bathing and Toilet Facilities: | |
(A) Private or shared facilities: | |
Wheelchair facilities | 25 (per fixture) |
Standard facilities | 15 (per fixture) |
(B) Full bathroom | 75 |
(C) Congregate bathing facilities: | |
First tub/shower | 80 |
Each additional fixture | 25 |
1 The size to be determined by the Chief Consultant, Geriatrics and Extended Care, as necessary to accommodate projected patient care needs (must be justified by State in space program analysis). |