Find Laws Find Lawyers Free Legal Forms USA State Laws

CFR

7.68—Firing line terminals test.

(a) Test procedures. (1) The contact resistance through each firing line terminal shall be determined.
(2) A 10-pound pull shall be applied to a No. 18 gauge wire that has been connected to each firing line terminal according to the manufacturer's instructions.
(b) Acceptable performance. (1) The contact resistance shall not be greater than 1 ohm.
(2) The No. 18 gauge wire shall not become disconnected from either firing line terminal.
Tips