7.102—Exhaust gas cooling efficiency test.
(a) Test procedures.
(1)
Follow the procedures specified in § 7.101(a).
(2)
Install a temperature measuring device to measure the exhaust gas temperature at discharge from the exhaust conditioner. The temperature measuring device shall be accurate to ±4 °F (±2 °C).
(3)
Determine the exhaust gas temperature at discharge from the exhaust conditioner before the exhaust gas is diluted with air.
(b) Acceptable performance.
(1)
The exhaust gas temperature at discharge from a wet exhaust conditioner before the exhaust gas is diluted with air shall not exceed 170 °F (76 °C).
(2)
The exhaust gas temperature at discharge from a dry exhaust conditioner before the gas is diluted with air shall not exceed 302 °F (150 °C).