               	               		285.824—How must I conduct self-inspections?
               		
               	 	
               	 	
               	 	               	 	               	 	               	 	               	 	
               	 	
    
        
        (a) 
         You must develop a comprehensive annual self-inspection plan covering all of your facilities. You must keep this plan wherever you keep your records and make it available to MMS inspectors upon request. Your plan must specify:
     
    
        
        (1) 
         The type, extent, and frequency of in-place inspections that you will conduct for both the above-water and the below-water structures of all facilities and pertinent components of the mooring systems for any floating facilities; and
     
    
        
        (2) 
         How you are monitoring the corrosion protection for both the above-water and below-water structures.
     
    
        
        (b) 
         You must submit a report annually to us no later than November 1 that must include:
     
    
        
        (1) 
         A list of facilities inspected in the preceding 12 months;
     
    
        
        (2) 
         The type of inspection employed, (i.e., visual, magnetic particle, ultrasonic testing); and
     
    
        
        (3) 
         A summary of the inspection indicating what repairs, if any, were needed and the overall structural condition of the facility.