1210.3—Requirements for cigarette lighters.
(a)
A lighter subject to this part 1210 shall be resistant to successful operation by at least 85 percent of the child-test panel when tested in the manner prescribed by § 1210.4.
(b)
The mechanism or system of a lighter subject to this part 1210 that makes the product resist successful operation by children must:
(1)
Reset itself automatically after each operation of the ignition mechanism of the lighter,
(2)
Not impair safe operation of the lighter when used in a normal and convenient manner,
(3)
Be effective for the reasonably expected life of the lighter, and
(4)
Not be easily overriden or deactivated.